Landlord EICR electrical inspection in Bournemouth, Poole
Rented homes in England need an electrical inspection at least every 5 years. This guide explains the rules, the report codes and the deadlines, with sources.
We're launching around Poole first. This guide is free to use whether or not you ever become a customer.
A private landlord in England must have the electrical installation in each rented property inspected and tested by a competent person at least every 5 years. The report, usually an EICR, must go to existing tenants within 28 days of the inspection and to new tenants before they move in. Councils can fine landlords up to £40,000 for a breach.[1]
The rules in brief
- Inspect and test at least every 5 years, using a competent person. The report, usually an EICR, sets the date of the next inspection.[1]
- Give the report to existing tenants within 28 days of the inspection, and to new tenants before they occupy the property.[1]
- Give a copy to a prospective tenant within 28 days of their request, and to the council within 7 days of its request.[1]
- Keep the report until the next inspection is due or has been carried out, unless a newer report replaces it.[1]
What does a landlord EICR cost?
UK cost guides put an electrical safety check (EICR) at roughly £100 to £250, with an average of about £200. The price depends on the size of the property and the number of circuits, and any remedial work is extra. Treat it as a guide, not a quote.[2]
What the report codes mean
- C1: danger is present and there is a risk of injury. Remedial work is required, and the report is unsatisfactory.[1]
- C2: potentially dangerous. Remedial work is required, and the report is unsatisfactory.[1]
- FI: further investigation is needed without delay.[1]
- C3: improvement recommended. No further work is needed for the report to count as satisfactory.[1]
If the report asks for work
Remedial work or further investigation must be completed within 28 days, or sooner if the report says so. Within 28 days of completing it, send the tenant and the council the original report together with written confirmation that the work is done, such as a satisfactory EICR.[1]
Penalties and who enforces the rules
Your local council enforces the rules. In this area that is Dorset Council for most of Dorset, and BCP Council for Bournemouth, Christchurch and Poole. The maximum financial penalty for a breach is £40,000.[1] Dorset Council's civil penalties policy, adopted on 29 July 2026, lists breaches of the electrical safety regulations at that statutory maximum.[3]
How My Chore Genie handles it
- We track the 5-year date from day one and book a qualified electrician well before it is due.
- We arrange access with your tenant.
- We send the report to your tenant within 28 days and file it with its next-inspection date.
- If the report asks for remedial work, we book it as a one-off job with the price shown first, and file the confirmation alongside the report.
What it costs with us
Inside our landlord lists, the EICR cost is spread across the five-year cycle, alongside the rest of your list. UK cost guides put an EICR at roughly £100 to £250, with an average of about £200. The plan also arranges access with your tenant, sends the report to them within 28 days, and files it with its next-inspection date. Remedial work is extra: it is quoted as a one-off job before it starts.
Our landlord plans start from £189 a quarter per rental property. Gas safety, EICR and alarm checks can be added so they are never missed. Labour for planned visits is included and parts are quoted first. Each rental property has its own plan. See landlord plans.
Frequently asked questions
How often does a landlord need an EICR?
At least every 5 years, by a competent person. The report sets the date of the next inspection.[1]
Do landlords have to have an EICR?
Yes. Private landlords in England must have the electrical installation in each rented property inspected and tested at least every 5 years.[1]
Is the landlord or the tenant responsible for the EICR?
The landlord. The duty to arrange the inspection, and to give the report to tenants and the council when required, sits with the private landlord.[1]
How much does an EICR cost?
UK cost guides put it at roughly £100 to £250, with an average of about £200, depending on the size of the property. Remedial work is extra. It is a guide, not a quote.[2]
Who has to receive the EICR?
Existing tenants within 28 days of the inspection, new tenants before they occupy the property, a prospective tenant within 28 days of asking, and the council within 7 days of asking.[1]
What happens if my EICR is unsatisfactory?
C1 and C2 findings need remedial work, and FI needs further investigation without delay. Complete the work within 28 days or sooner if the report says so, then send the tenant and council written confirmation.[1]
Does a C3 code mean I have to do work?
No. C3 means an improvement is recommended. Further work is not required for the report to count as satisfactory.[1]
What is the penalty for not complying?
The maximum financial penalty is £40,000.[1]
Do you work in Bournemouth, Poole and Christchurch?
We are launching around Poole first, with Bournemouth and Christchurch assessed individually. Register your interest and we will tell you when we reach your area.